Campus security monitoring system solutions and design ideas!

With the development of social economy, criminals are increasingly rampant, bold, and increasingly rampant. In order to protect your life and property from losses, the work of safety precautions should be mentioned on the first schedule. In terms of major universities and colleges, there are common characteristics: scattered venues, large area, few management personnel, large numbers of students, good liveliness, and poor awareness of prevention. There are hidden dangers in public places such as college laboratories, student activity centers, sports fields, libraries, student dormitories, restaurants, and teaching buildings.

1. Students have a fire due to poor knowledge of electricity, or candles in the middle of the night;

2. Stolen incidents (CDs, cameras, computers) often occur in student dormitories

3. Bicycle loss events often occur in colleges and universities. Usually, no carports are managed;

4. Theft of wallets on the library's baggage racks often occurs;

5. Incidents of stolen property from the laboratory often occur;

6. Occurrence of riots in restaurants and sports fields occurs frequently;

It is imperative to install anti-theft visual monitoring and fire monitoring facilities so that the combination of air defense and technical protection is imperative.

In view of the numerous security risks existing in colleges and universities, we have conducted in-depth analysis and inspections, in order to effectively maintain the order and safety of the campus, ensure the smooth implementation of school teaching and research work, and create a better security environment for the students' lives and learning. , We provide you with a full range of solutions - solutions for common cable monitoring systems.

1. A monitoring point is set up in the apartment building of a student apartment. The apartment administrator can monitor the exit and entry of the personnel in the apartment building by monitoring the secondary control, especially during the night and during the student's class. It also greatly saves manpower; installing an alarm can provide timely alarm (such as fire) in the event of an accident;

2. Set up monitoring points at the library depository and make video recordings. Used for immediate prevention or as an objective basis for post-analysis processing in the event of an emergency;

3. Set up monitoring points at the carport entrance and exit, and make video recordings for anti-theft and future viewing;

4. Establish monitoring points in the laboratory and make video recordings. The laboratory management teacher can monitor each laboratory in the computer room by monitoring the secondary control, which facilitates management;

5. Monitoring points, monitoring heads and alarms are set up in restaurants and stadiums. The flow of people in these places is relatively large. Managers can keep abreast of the situation at the scene through monitoring and deputy controls.

6. According to the college’s specific conditions, monitoring points, monitoring heads, alarms, and deputy control points are set up in special locations to improve the college’s technical protection facilities.

7. The establishment of monitoring and management center, all monitoring signals are integrated here, through the TV wall to monitor the site of all monitoring site dynamics, the need to record the monitoring point for hard disk video, as an objective basis for subsequent analysis and processing.

First, campus network monitoring program design ideas

As a special public place, campuses have a common feature: scattered venues, large area, few management personnel, large numbers of students, good liveliness, and poor awareness of prevention. Schools, student activity centers, sports fields, libraries, student dormitories, restaurants, teaching buildings and other public places have security risks:

Students have a fire due to poor knowledge about electricity or candles in the middle of the night.

Stolen incidents (CDs, cameras, computers) often occur in student dormitories;

Losses from bicycle accidents often occur in colleges and universities. Usually, no carports are managed;

Cases of stealing purses on the library's baggage racks often occur;

Incidents of stolen property from the laboratory often occur;

The riots in restaurants and sports fields often occur...

It is imperative to install anti-theft visual monitoring and fire monitoring facilities in school buildings and public places so that the combination of air defense and technical protection is imperative.

We have conducted in-depth analyses and investigations on the numerous security risks that exist in various schools. In order to effectively maintain the order and safety of the campus, we ensure the smooth implementation of teaching and scientific research work in schools and create better security for the students' lives and learning. Environment, we provide you with a full range of solutions - closed-circuit network monitoring system solutions.

Second, system design goals

When designing a network monitoring system, according to the school’s basic needs for the system, it is based on a rational structure, safety and reliability, mainstream products, low cost, and low maintenance, and provides advanced, safe and reliable information for your school. Efficient system solutions.

Reasonable architecture: It is to adopt advanced and reasonable technologies to structure the system so that the entire system runs safely and steadily, and has good conditions for expansion in the future.

Stability and security: This is the problem that every school cares about most. Only a stable operation system can ensure the smooth operation of the school network monitoring system. The advanced technology of the system is the guarantee and foundation of the high performance of the system, and at the same time it can effectively reduce the troubles of the personnel and system maintenance personnel. Good scalability is for the development of users. With the increase in the application time of security systems, the requirements for security systems will be even higher in the future. Extensibility guarantees that when the user has more requirements, the new equipment introduced can smoothly work with the equipped equipment to further expand and improve the performance of the system.

Mainstreaming of products: Whether the system adopts mainstream products today affects the overall quality of the system and whether it can obtain good technical support and complete technical documentation in the future.

In equipment selection, we will mainly rely on the specific needs of schools, taking into account the technological advancement of product manufacturers, whether the product is a mainstream product, the integrity of the original manufacturer’s product technical data, the original manufacturer’s technical support and product manufacturing. The school's development prospects. All of these are the conditions for ensuring that users receive good technical support, and they are also the basic conditions for ensuring the investment of users.

Low cost and low maintenance: Strive to have a good performance to price ratio, the products used should be simple, easy to operate, easy to maintain, and high reliability.

Whether the system has a good performance-cost ratio is an important basis for judging the merits of a system. The ease of operation and ease of maintenance of the system is a condition for ensuring that non-professionals use a good system. High reliability is the basic requirement for ensuring the operation of the system, and it is also the safeguard of easy maintenance.

For a typical network monitoring system, the following functions will be achieved when completed:

Set up monitoring points at the library depository and make video recordings. Used for immediate prevention or as an objective basis for post-analysis processing in the event of an emergency;

Set up monitoring points in the laboratory and make video recordings. The laboratory management teacher can monitor each laboratory in the computer room by monitoring the secondary control, which facilitates management;

Monitoring points, monitoring heads and alarms are set up in restaurants and stadiums. The flow of people in these places is relatively large. Managers can keep abreast of the situation at the scene through monitoring and deputy controls.

According to the college’s specific conditions, monitoring points, monitoring heads, alarms, and deputy control points are set up in special locations to improve the college’s technical protection facilities.

A monitoring point is set up in the apartment building of a student apartment. The apartment administrator can monitor the exit and entry of the personnel in the apartment building by monitoring the secondary control, especially during the night and during the student's class. It also greatly saves manpower; installing an alarm can provide timely alarm (such as fire) in the event of an accident;

Each camera is an information point, which is connected to the campus network through a network cable, and then monitors each camera through a monitoring PC. It can be monitored remotely through a browser, and PC monitoring can be set up at the teaching office, laboratory building, and library. point.

Third, system design principles and basis

The main basis of our design plan is to understand part of the user's needs and understand the standard of the IP network monitoring system, and propose a set of design ideas and network solutions. The monitored cable connection is a network cable. Using the network that the school has already built for the campus network can reduce the amount of construction work.

The protective cover is divided into indoor type and outdoor type. The indoor protective cover is mainly dustproof, and some also have a covert effect, so that the monitoring occasions and objects are not easily perceived and monitored. The functions of the outdoor protective cover include sun protection, rain protection, dust prevention and antifreeze. General outdoor enclosures are equipped with temperature relays. When the temperature is high, the fan is automatically turned on. When the temperature is low, it is automatically heated. When it rains, it can be manually controlled by the wiper. Some outdoor protective cover glass can also be heated. When there is frost on the hood, it can be heated to defrost.

Fourth, the system power supply and control room requirements

In order to ensure the normal and stable operation of the monitoring system, the system adopts an on-line UPS for centralized power supply; the monitoring server and the recording server use separate power supply circuits; the trunk adopts AC220V power supply, and the transformer uses the transformer to provide power supply at the nearby site; the central control room must be equipped with communication, safety, and Fire and other equipment; Central control room must be installed separately air-conditioning device, to ensure that the temperature of the control room is between 16 ~ 28 °C, relative humidity is not greater than 85%; control room, indoor lighting is sufficient, the illumination should not be less than 300 Lux; control room other Equipment and metal enclosures must also be equipotentially connected to ensure personal and equipment safety in the control room.

Application Solution of Modern Digital Campus Monitoring System

With the rapid development of technology and the expansion of applications, the accuracy of cameras has become higher and higher, and the degree of automation has become stronger. Nowadays, digital classrooms have become an advanced means of detecting and communicating teaching quality in schools and other training institutions. It can provide principals and leaders in charge of teaching work with a set of credible materials for the entire teaching process. It is particularly helpful for the cultivation of young teachers. It is an advanced means of improving the quality of teaching and achieving results in 45 minutes.

The digital classroom is based on a color camera controlled by an electric pan/tilt head, and is equipped with a multi-fold three-variable lens (electrically adjusted aperture, distance, and magnification) and a high-sensitivity pickup to provide a convenient and practical video recording system.

The campus monitoring system is an integrated system composed of multiple digital classrooms. The system is equipped with cameras, pickups, and speakers in important locations in each classroom and campus. It provides unobstructed views of every corner of the campus. It is taught and managed. An advanced audio and video transmission system.

The combination of this system and closed-circuit television system can enable each classroom to achieve the exchange of audio and video, which is not only conducive to the exchange of teaching content, but also conducive to the conduct of educational administration and examination management, daily school management, observation classes, demonstration classes and young The cultivation of teachers plays a decisive role.

(A) The main functions of the campus monitoring (president evaluation) system:

1. Managers can monitor, monitor, intercom, and facilitate examinations for any classroom.

2. In addition to teachers and students in the classroom, there are no other filming and lecturers. The entire work is done through front-, rear- and ceiling-mounted cameras and highly sensitive pickups. The attendants do not feel any interference.

3. The main control room can control the lens in any classroom to perform full-range (360°) rotation, zooming, variable pitch, and close-up shots;

4. A plurality of monitors monitor the shooting pictures of different cameras, and monitor and record the entire course of teaching in the classroom from different directions;

5. The control personnel can take all-around filming and video recording of the teacher's teaching methods, voice, writing and student activities in the classroom;

6. The main control room application video host can perform video recording on any classroom;

7. The control personnel can operate the electric pan-tilt head and multiple zoom lens to take close-up shots of the teacher's actions, student's answers, and the contents of the board.

8. The campus plan can be used in the main control computer, which can conveniently pull the content taken by any camera into the screen.

9. It can synchronously record the sound in the classroom;

10. Record all surveillance points in the main campus;

11. The main control room can organize management personnel to listen to classes in a certain class, without affecting the normal class of the class;

12. Vice-control (the principal's office, conference room) has the above functions;

13. The intercom function, monitoring (student self-study, when there is no teacher) found that the classroom discipline scattered, the main and deputy control can speak to the class;

14. The control personnel can process the recorded data into teaching courseware by simply processing the video data.

15. In combination with CCTV systems, audio and video are delivered to each other.

16. Classroom personnel can use keystrokes to request an intercom with the management center.

(two). Campus monitoring system main use:

1. Monitor the discipline of each class during the exam;

2. Observe the disciplinary situation in each class during self-study;

3. Monitoring of various security agencies such as finance and warehouses;

4. Monitor the teacher's class situation, understand the teacher's teaching attitude, characteristics, advantages and disadvantages;

5. Organize teachers to listen to a class;

6. Combined with CCTV system, each classroom can be retransmitted to each other;

7. Anti-theft monitoring;

8. Video recording of important teachers' important courses to help other teachers observe and learn;

9. Model lessons for external special teachers;

10. Organize teaching managers and academic leaders to listen to young teachers in the main control room to record the advantages, disadvantages, and practical problems after class comparison and improvement;

11. The teaching and research team of the professional teaching and research group will discuss and revise the course;

12. The information retention of the school key courses;

13. The major activities of the school include experts and scholars to give lectures, political ideological education and patriotism education;

14. In conjunction with closed-circuit television systems, digital classroom activities and courses are broadcast live to the school;

15. The recording of the excellent open class program that the school sends to the electric education institution to review;

16. Exchange of information between school retention files and sibling schools.

17. Connect the campus network to the Internet, and monitor any monitoring point in the school anywhere in the world.

(C) The principle of campus monitoring system

The campus monitoring system is mainly composed of four parts: the camera part, the transmission part control part, and the display and recording part. The camera includes a color camera (with three variable lenses), an indoor all-around head, a dust cover, etc. The transmission section is mainly composed of a video server, and the control section includes image switching, motion control, and so on.

(1) Camera section

The camera part is the front part of the TV monitoring system and is the 'eye' of the entire system. The camera changes the monitored content to an image signal and transmits the digital audio and video signals to the monitoring and storage equipment of the control center through the video server. The camera part is the original signal source of the system. The quality of the camera part and the quality of the generated image affect the quality of the entire monitoring system. Therefore, the television monitoring system adopts a color camera integrated device with high definition and high sensitivity, an aperture, focusing, zooming and three variable lenses, and an electric indoor rotating 350 degrees in the horizontal direction and ±45 degrees in the vertical direction. PTZ; with a dust cover with anti-theft, anti-damage, dust-proof performance, and so on.

(2) Transmission section

The transmission part of the television monitoring system mainly consists of the transmission of image signals, the transmission of sound signals, and the transmission of control signals for controlling cameras, lenses, and pan-tilts. In this program, we take into account some of the specific circumstances of the school. We will use the Transcend Video Server of the Garment Digital Technology Co., Ltd. to transmit images, sounds, and control signals. Its main advantage is that the image will not be generated after transmission. Noise distortion can ensure the clarity and gray level of the original image signal. It mainly uses the school's existing local area network for transmission, which not only saves costs to the maximum but also eliminates the cumbersomeness of laying cables repeatedly.

(3) Control section

There are two options for the control section. One is to use the computer's mouse and keyboard for control, and the other is to use a dedicated control keyboard and matrix host to control.

In order to save system cost and extend the equipment's elimination cycle as much as possible, we recommend the use of the first program, using a computer to control.

(4) Display and record section

The main equipment in the display section is a computer monitor and a large-screen television (or projector). A large-screen television is used as a main display, and a computer display is used as an auxiliary display to facilitate management personnel in controlling the front-end monitoring point.

The recording part consists mainly of storage hosts and disk arrays. Each storage host can synchronously store 80 channels of audio and video, and can set the recording mode such as schedule recording by the storage host to save hard disk space.

6 Molds Baguette Pan

Perforated bread Baking Sheet is Available In Optimized Dimension and material. For example, width and length will be customized to your designation and ovens. Material strength will be different due to different thickness of aluminum steel. Perforated surface for baking sheet will be punched by hole punching machines. Experienced workers make sure smooth and light sheet surface for baking sheet. Baking sheet has special internal non-stick Xynflon coating allows to professional use for baking and easy wash.